Skip to main content
Installing Current Sensors

Instructions for placing the current sensors correctly.

Updated over 2 months ago

1. Amperage Check

Check if the amperage of the current sensors and the current sensor cables match the electric motor. The image below shows the appropriate sensor size for different amperage ranges.

2. Connecting to the DAQ

Plug the connectors of the current sensor cables into the corresponding ports of the DAQ and route the sensor cables to the corresponding phase wires of the motor.

Notice Plugging a connector into the wrong port on the DAQ is prevented by red insert pieces in the connectors. The current sensor connects only to the

corresponding port on the DAQ.

3. Positioning the Sensor

Open the bayonet coupling of the current sensor. Position the current sensor around the phase wire. A sticker on the current sensor shows the correct orientation.

4. Closing the Sensor

Close the current sensor by pressing the bayonet coupling shut. The current sensor will now hang loosely around the phase wire.

Notice For multiple phase wires, place the sensor around a single wire per phase.

Did this answer your question?